3 clutchstopposition, 4 comparetpdiffshaft – Lenze E94AxHE Technology Application Synchronism User Manual

Page 56

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

56

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.14.3

ClutchStopPosition

4.14.4

CompareTPDiffShaft

Is an instance of

Function

L_SdSetPosition

Conversion of the set position after decoupling selected in the real units of the

machine via C03679 into a position in [increments].



Virtual clutch (C 36)

Parameter

Possible settings

Information

C03679

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03680

String of digits

Position unit

• Read only

C03681

-2147483647

2147483647 Status

• Read only

Is an instance of

Function

L_TbCompare

Mark synchronisation (master value):

Comparison of the determined TP difference and the TP limit parameterised in

C03651 for the status message "TP limit exceeded" via C03655.



Mark synchronisation (master value) (C 34)

Parameter

Possible settings

Information

C03650

Comparison function

0 dnIn1 = dnIn2
1 dnIn1 > dnIn2

Lenze setting

2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|

Advertising