3 clutchstopposition, 4 comparetpdiffshaft – Lenze E94AxHE Technology Application Synchronism User Manual
Page 56
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
56
L
EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.3
ClutchStopPosition
4.14.4
CompareTPDiffShaft
Is an instance of
Function
L_SdSetPosition
Conversion of the set position after decoupling selected in the real units of the
machine via C03679 into a position in [increments].
Parameter
Possible settings
Information
C03679
-214000.0000
unit
214000.0000 Position value
• Initialisation: 0.0000 unit
C03680
String of digits
Position unit
• Read only
C03681
-2147483647
2147483647 Status
• Read only
Is an instance of
Function
L_TbCompare
Mark synchronisation (master value):
Comparison of the determined TP difference and the TP limit parameterised in
C03651 for the status message "TP limit exceeded" via C03655.
Mark synchronisation (master value) (C 34)
Parameter
Possible settings
Information
C03650
Comparison function
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2
Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|