4.14.9
ElectricalShaftVal
Is an instance of
Function
L_SdSetAxisVelocity
Master value processing (C 33)
Parameter
Possible settings
Information
C03590
-214748.3647
214748.3647 Status
• Display of the bit-coded output
signal dnState.
C03591/1
String of digits
Position unit
• Read only
C03591/2
String of digits
Speed unit
• Read only
C03592
-214748.3647
unit/t
214748.3647 Speed at the output
• Read only
• Is generated from the speed
signal dnSpeedOut_s.
C03593
-214748.3647
unit/t
214748.3647 Master speed
• Read only
• Is generated from the speed
signal dnSpeedIn_s.
C03597
-214748.3647
unit
214748.3647 Measured cycle
• Display of output signal
dnTpTpDistance_p in real unit of
the machine.
C03598
-214748.3647
unit
214748.3647 Measured Tp deviation
• Display of output signal
dnDifference_p in real unit of the
machine.
C03599
-214748.3647
unit
214748.3647 Position at the output
• Display of the dnPosOut_p output
signal in the real unit of the
machine.
C03604
TP deviation detected
• Display of output signal
bTpDiffRecogn.
0 FALSE
1 TRUE
C03605
Start of cycle
• Display of output signal bZeroPos.
0 FALSE
1 TRUE