Wiring the connectors, Figure 22 - idm system wiring – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 57

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
57
Connecting the Kinetix 6000M System
Chapter 5
Figure 22 - IDM System Wiring
The colored rings on the hybrid cable connector and the mating cable must
match: red-to-red or green-to-green.
Hand-tighten the knurled collar on a hybrid cable approximately 45 degrees to
fully seat and lock the connector.
Wiring the Connectors
Use these guidelines as a reference when wiring the hybrid cable to the IPIM
module.
Figure 23 - 2090-CHBIFS8-12AAxx Hybrid Cable
1. Route the cable/wires to the module.
2. Insert wires into connector plugs.
3. Tighten the connector screws.
Refer to
for torque specifications.
4. Gently pull on each wire to make sure it does not come out of its terminal;
reinsert and tighten any loose wires.
5. Insert the connector plug into the module connector.
PORT 1
PORT 2
NETWORK
IDM to IDM Hybrid Cable
(2090-CHBP8S8-12AAxx)
IPIM Module
IDM Unit
IDM Unit
Network Terminator
Last IDM Unit
(2090-CTSRP)
Network Cable
(2090-CNSRPRS-AAxx)
Network Cable to First IDM
(2090-CNSSPRS-AAxx)
Hybrid Terminator
Last IDM Unit
(2090-CTHP8)
IPIM to IDM Hybrid Cable
(2090-CHBIFS8-12AAxx)
(Catalog numbers are in parenthesis.)
42- (white/blue)
42+ (blue)
CN- (white/brown)
CN+ (brown)
SH2 (drain)
RTN (pink)
OUT (white/pink)
SE1 (orange)
SE2 (yellow)
SE- (violet)
SH3 (drain)
DC+ (brown)
PE (green)
DC- (grey)
DC+
DC-
42-
42+
SH3
OUT
CN-
CN+
SE1
SE2
SE-
SH2
RTN
PE
DC Bus
Co
nt
ro
l
Po
w
er
Communic
ation