Install terminal in panel – Rockwell Automation 2711 Standard PanelView Operator Terminal User Manual User Manual
Page 136

136
Publication 2711-UM014G-EN-P - September 2008
Chapter 6 Installing the PV300 Micro Terminal
Install Terminal in Panel
Follow these steps to install the PV300 Micro in a panel.
1. Cut an opening in the panel by using the panel cutout template
provided with the terminal and remove sharp edges or burrs.
2. Make sure the sealing gasket is properly positioned on the
terminal, particularly around the mounting studs as shown.
This gasket forms a compression type seal. Do not use sealing
compounds.
3. Place the terminal in the panel cutout.
4. Install the four self-locking nuts, and tighten hand tight.
5. Alternately tighten the self-locking nuts until the terminal is held
firmly against the panel.
ATTENTION
•
Disconnect all electrical power from the panel before making cutout.
•
Make sure area around the panel cutout is clear.
•
Take precautions so that metal cuttings do not enter any components
already installed in panel.
•
Failure to follow this warning may result in personal injury or damage
to the panel components.
Sealing Gasket
Sealing Gasket
Self-locking Nuts (4
used, 6 provided)