Configuration blocks 37–39 – Rockwell Automation 5370 Color CVIM Communications Manual User Manual
Page 207

Appendix D
Configuration Data
D–8
Table D.6 shows the function of each word in the reference line 1–3
configuration blocks.
Table D.6
Configuration Blocks #37–39 – Reference Lines 1–3
Remote I/O
& RS–232
Word #
Bit #
Definition
Usage
Notes
0
0–15
Block Transfer Signature
1
0–7
Reserved
0 = Disabled
1
8
Enable
0 = Disabled
1 = Enabled
1
9–15
Reserved
2–7
0– 15
Reserved
8
0–7
X–Line High Threshold/
Gradient Threshold
0–197
8
8–15
Image number
0–37
9
0–7
Reserved
9
8–15
X–Line Low Threshold/Scale Factor
10
0–15
X–Line Head X Position
From upper left corner.
11
0–15
X–Line Head Y Position
From upper left corner.
12
0–15
X–Line Tail X Position
From upper left corner.
13
0–15
X–Line Tail Y Position
From upper left corner.
14
0–15
Reserved
Y–Line High Threshold/
15
0–7
Y–Line High Threshold/
0–197
15
0–7
Gradient Threshold
0–197
15
8–15
Image number
0–37
16
0–7
Reserved
16
8–15
Y–Line Low Threshold/
Scale Factor
17
0–15
Y–Line Head X Position
From upper left corner.
18
0–15
Y–Line Head Y Position
From upper left corner.
19
0–15
Y–Line Tail X Position
From upper left corner.
20
0–15
Y–Line Tail Y Position
From upper left corner.
21
0–15
Reserved
Configuration Blocks 37–39