Configuration blocks 40–45 (cont’d) – Rockwell Automation 5370 Color CVIM Communications Manual User Manual
Page 209

Appendix D
Configuration Data
D–10
Table D.8
Configuration Blocks #41, 43, & 45 – Reference Windows 1–3
Remote I/O
& RS–232
Word #
Bit #
Definition
Usage
Notes
0
0–15
Block Transfer Signature
1
0–15
Feature 1 Search Window X
Location
Relative to the upper left corner.
2
0–15
Feature 1 Search Window Y
Location
Relative to the upper left corner.
3
0–15
Feature 1 Search Window Width
4
0–15
Feature 1 Search Window Height
5–8
0–15
Reserved
9
0–7
Reserved
9
8–15
Feature 1 Score
0 = Minimum Value
100 = Maximum Value
10–19
0–7
Reserved
20
0–15
Feature 2 Search Window X
Location
Relative to the upper left corner.
21
0–15
Feature 2 Search Window Y
Location
Relative to the upper left corner.
22
0–15
Feature 2 Search Window Width
23
0–15
Feature 2 Search Window Height
24–27
0–15
Reserved
28
0–7
Reserved
28
8–15
Feature 2 Score
0 = Minimum Value
100 = Maximum Value
29–38
0–15
Reserved
39
0–15
Feature 3 Search Window X
Location
Relative to the upper left corner.
40
0–15
Feature 3 Search Window Y
Location
Relative to the upper left corner.
41
0–15
Feature 3 Search Window Width
Configuration Blocks 40–45
(cont’d)