To adjust the row cleaner:

1.

Determine the height adjustment required. Measure
from the lowest tine to the ground. Determine the
desired new measurement.

2.

Support most or all of the weight of the arm to
prevent injury and ease the adjustment. Loosen
bolts

on UMC-RC. Remove bent pin

on UMRC.

3.

Support arm at desired height.

4.

UMRC: Slide adjustment tube

until cross-tube

contacts arm at target height. Insert bent pin

in

whichever hole pair is most in alignment.

5.

UMC-RC: Slide the down-stop

on the arm

:

- back toward the pivot for shallower cleaning, or
- forward toward the tines for deeper cleaning.
Tighten the bolts

. Each possible hole pairing

adjusts the tine height by about

3

4

in. (19 mm).

6.

Check the new height measurement.

Refer to Row Cleaner manual 204-085M-A for further
information on use, adjustment and maintenance of row
cleaners.

Unit-Mounted Coulter Adjustments

Note: Applies only to 10HDP and 25P Series.

Note: Unit-Mount Coulters are not factory-installed.

Check alignment and depth prior to first use.

Note: For frame-mounted coulter adjustments, see

Frame-Mounted Coulter Adjustments” on
page 66.

Coulter Depth Adjustment
The ideal operating depth for unit-mounted coulters is

1

4

in. above opener depth. Although they may have

originally been set to this depth, coulter (and opener)
blades wear with time, and may need adjusting.

Adjusting the coulter depth is accomplished by
re-mounting the coulter blade in one of the six mounting
holes arranged in a staggered pattern in the coulter
bracket.

Refer to Figure 92 and Figure 93

Raise YP40 planter and install cylinder locks before
working on coulters. Row unit may be fully lowered or
locked up. Do not attempt to move blade when the
current or new position causes it to contact the ground
during the adjustment. Be careful around the front end of
row units. Coulter blades may be sharp.

Figure 91

UMC-RC: Row Cleaner Adjust

27343

6

4

5

5

2

1

3

2

6

4

5

Figure 92

10HD Series Unit-Mounted Coulter

29124

7

Advertising