10hd, 25p meter wheel replacement – Great Plains YP4025F-1670 Operator Manual User Manual

Page 87

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Adjustments

83

2014-09-08

Table of Contents

Index

401-571M

10HD, 25P Meter Wheel Replacement
Choose the correct seed meter wheel for the type of
seed you will be using. Be sure to use the same wheel
type on all meters.

Meter Wheels Not Interchangeable:
Seed meter wheels for the 10HD and 25P Series row units are
made of a green color material and are not interchangeable
with the other Great Plains seed meter wheels, such as Black
for 20P Series. Use only green wheels in 10HD and 25P Series
row units.

1.

Clean out meter. For more information, see “10HD,
25P Meter Removal
” on page 81.

Refer to Figure 107

2.

Push in spring-loaded wheel retainer and make

1

4

turn. Pull off wheel retainer and spring.

Refer to Figure 108

3.

Pry the seed meter wheel out about

1

4

inch (6 mm)

using the tool stored under the walkboard, and spin
backward to clean out seeds from top pockets.

Note: If wheel is not free of all seed, wheel removal is

much more difficult, as pocketed seeds will shear
against meter parts.

Refer to Figure 109

4.

Remove seed meter wheel.

Figure 107: 10HD, 25P:

Singulator Wheel Retainer

22911

Figure 108: 10HD, 25P:

Pry Meter Wheel

22913

Figure 109: 10HD, 25P:

Remove Wheel

25274

Advertising