Unit must remain in an upright position during all

rigging and moving operations. Unit must be level

for proper condensate drainage; therefore, ground-

level pad or field-supplied mounting curb must be

level before setting unit in place.

ROOFTOP INSTALLATION

CAUllONt When ìnstaHjjig «mt

<m

a rooftop,

be sure rooi wiU soppori. ibe additional weight.

Refer

to

Produot Data Digest to obtain total

weight and comer weight infonrnation.

When installing a Model 48GH/GL end-

discharge unit with a field-supplied downflow

plenum, a field-supplied roof-mounting curb must

be installed on and flashed into roof before unit

installation.

When installing a Model 48GH/GL end-

discharge unit without a downflow plenum, place

unit on a level base that provides proper support. On

flat roofs be sure that unit is located at least 4 in.

above highest expected water level on roof to pre­

vent flooding. Consult local codes for additional

installation requirements.
GROUND-LEVEL INSTALLATION - Place

unit on a solid, level concrete pad that is a minimum

of 4 in. thick and that extends approximately 2 in.

beyond casing on all 4 sides of unit. Do not secure

unit to pad except when required by local codes.
CLEARANCES — The required minimum oper­

ating and service clearances are shown in Fig. 1.

CAUTION: Douot resïîicî ccsdenser air^ow:.

An air restriction at either outdoor-air inlet (the

entire surface of the outdoor coil) or fan dis­

charge can he detfinaeniai to compressor hfe.

Condenser Ian discharges thru top of unit. En­

sure that fan discharge does not recirculate to

condenser coil. Do not locate unit in either a corner

or under a complete overhead obstruction. Mini­

mum clearance under a partial overhang (such as a

normal house roof overhang) is 3 ft above vent cap.

Do not locate unit where water, falling ice or snow

from an overhang or roof will damage or flood the

unit. Do not locate unit where grass, shrubs, or

other plants will interfere with airflow either into

or out of unit.

CONDENSATE DISPOSAE

NOTE. Ensure that condensate-water disposal

methods comply with local codes, restrictions and

practices.

Models 48GH/GL dispose of condensate water

thru a 3/4-in. MPT drain fitting. See Fig. 1 for

location.

Install a 3-in. trap at drain fitting to ensure

proper drainage. See Fig. 3. Make sure trap outlet

is at least 2 in. lower than unit drain pan connection

to prevent pan from overflowing. Prime trap with

water.

If the installation requires draining condensate

water away from the unit, connect a drain tube

using a minimum of 7/8-in. OD copper tubing.

3/

no

at

ru
ro

on

W

aw

FRC

VI

du

CO

lo(

St£

tO|

bl(

Table 1 — Installation

MODEL 48

GL018

GL024

GH024

GL030

GH030

GL036

GH036

SERIES

320

320

320

320/330

320/330

320/330

520/530 1 620/630

320/330

520/5

DIMENSIONS |ft-in.)

A

4-5-578

4-5-5/8

B

2-6-3/8

3-4-3/8

C

3-2- 1/8

3-5-1/8

D

1 -4

1 -7

E

1 -4

1-1 1/4

F

0-7- 1/4

*

0-8-7/8

G

0- 11

0-10

H

1-0-5/8

1-5-5/8

K

0-1- 3/32

0-1 3/8

FIELD-SUPPLIED FILTER

SIZE (sq. in.)*
Standard Disposable Type

289

396

396/433t

522

522

576

576

576

583/722f

583/72

Cleanable- or

High-Capacity Type

188

257

257/281t

339

339

374

374

374

379/469t

379/461

OPERATING WT (lb)

320

325

375

375

375

380

380

380

475

475

SHIPPING WT (lb)

330

335

385

385

385

390

390

390

485

485

HEATING INPUTS (Btuh)

Min

40,000

40,000

60,000

40,000

60,000

60,000

60,000

60,000

100,000

100,00

Max

50,000

50,000

75,000

50,000

75,000

75,000

75,000

75,000

1 25,000

125,00

COOLING AIRFLOW (Cfm)

600

825

825

1088

1088 ^

1200

1200

1200

1215

1215

EXTERNAL STATIC

PRESSURE (in. wg)

0 10

0 10

0 10

0 15

0 15

0 15

0 15

0 15

0 15

0 15

^Recommended, field-supplied air filter areas shown are based on either cooling airflow at a velocity of 300 ft per

minute or heating airflow at a temperature of 60 F. depending on whichever value is larger Air filter pressure drop
should not exceed 0 08 in wg for unit to produce rated cooling performance

fWhen Models 48GH024 or GH036 are installed for operation at minimum rated heating input, recommended

minimum air filter area Is the smaller sq in figure shown for each type of filter Larger figures shown are mini-

h(

tAI

or