background image

CONT CONTACTOR
IFR INDOOR FAN RELAY
CC COOLING COMPENSATOR

TC THERMOSTAT COOLING

---------- FACTORY CONTROL WIRING
---------- FIELD POWER WIRING
---------- FIELD CONTROL WIRING

O COMPONENT CONNECTION

FIELD SPLICE

A92407

Fig. 5—Control Circuit Connection (018)

START-UP

Step 1—Start-up Procedure

1. Back seat (open) liquid and suction line service valves.

2. Set thermostat selector switch at OFF.

3. Set room thermostat to desired temperature.

4. Close electrical disconnects, energizing entire system.

5. Set room thermostat at COOL and fan switch as desired, FAN

or AUTO. Operate unit for 15 minutes, then check system
refrigerant charge. See Refrigerant Charging section.

Motors and controls operate satisfactory in the 253-v/187-v range.

Do not connect charging hoses during initial start-up procedure.

(Loss of charge from this procedure may result in capacity

reduction.) If necessary to add manifold gages for servicing, refer

to the service manual for bypass method of returning charge to
system.

Step 2—Sequence of Operation

When thermostat "calls for cooling," thermostat contacts close,

energizing contactor holding coil from 24-v external power source.

Contacts close, energizing compressor motor and condenser fan
motor with supply voltage.

When thermostat is satisfied, contacts open, de-energizing contac­

tor holding coil and, in turn, breaking supply voltage circuit. All

motors should stop. In 024 size applications the lock-out relay

prevents restart for up to 5 minutes. Refer to presale literature.

Step 3—Refrigerant Charging

Refer to information on unit rating plate.

CTD - COMPRESSOR TIME DELAY
IFR - INDOOR FAN RELAY
DTS - DOME THERMOSTAT
CONT - CONTACTOR

FACTORY WIRING
FIELD WIRED
POWER WIRING

SPLICE CONNECTION

A88547

Fig. 6—Control Circuit Connection (024)

A

CAUTION

To prevent personal injury, wear safety glasses and gloves

when handling refrigerant. Do not overcharge system. This
can cause compressor flooding.

SERVICE

Access to all controls and unit components is through rear access

panel.

A

WARNING

Because of possible damage to equipment or personal injury,

maintenance should be performed by a trained technician.

Consumer service is recommended only for filter cleaning/re-

placement.

Minimum maintenance to be performed:

1. Check condenser coil for cleanliness each month during

cooling season. Clean as necessary but at least once at

beginning of each season.

2. Check blower motor and wheel for cleanliness and proper

lubrication each cooling season. Clean as needed.

3. Check electrical connections for tightness and controls for

proper operation each cooling season. Service as necessary.

A

WARNING

As with any mechanical equipment, personal injury can result
from sharp metal edges, etc., therefore, be careful when

removing parts.

NOTE:

Never operate unit more than 2 minutes with rear door

removed as unit damage may result.