START-UP INSTRUCTIONS

38GF Units

— Crankcase heater should be ener­

gized a minimum of 4 hours before starting unit.

Start Procedure (38GC and 38GF)

1. Backseat (open) liquid and suction line service

valves.

CAUTiON:

Seme? v's.tves have Teflon

wassher. Do not ovefíígJtteo (fhiget

seal)» Dei not exceed 10 fi4b torque

when íjghíenMg,

2. Close electrical disconnects energizing entire

system.

3. Set room thermostat to desired temperature.

4. Set room thermostat to “Cool” and fan switch

as desired (“Fan”) (“Auto”).

Motors and controls will operate satisfactorily

10% above and 10% below unit voltage (Table 5).

Do not connect charging hoses to capillary

controlled system during initial start procedure.

(Loss of charge from this procedure may result in

capacity reduction.) If necessary to add manifold

gages for servicing, refer to Carrier Standard

Service Techniques Manual, Chapter 1, pages 1-5,
Fig. 8, for bypass method of returning charge to

system.

COMPRESSOR

38GC101 and 38GC,GF102,103 Unit Single-Phase
Compressors

of the split capacitor (PSC) type

require an equalized system pressure to start. (See
Physical Data table for compressor type.)

When supply voltage is within 10% limit and

compressor does not start, give compressor a

temporary capacitance boost. See Carrier Standard

Service Techniques Manual, Chapter 2, for details.

Use a 130 mfd start capacitor. Run compressor for

10 minutes then shut off and allow system pressure

to equalize. Try restarting without boost capacitor.
If after two attempts (without boost capacitor) the

compressor does not start, add an accessory start
capacitor relay package.

Compressor Protection

38GF UNITS have a high pressurestat located on

liquid line and a low pressurestat located on
suction Hue. High pressurestat has black leads and
low pressurestat has blue leads. High pressurestat
settings are" cutout, 428 ± 5 psig; cut-in, 320 ± 20
psig. Low pressurestat settings are: cutout, 27+ 4
psig; cut-in, 60 -t- 15 psig, -0 psig.

38GC UNITS have a high-pressure relief valve

located in compressor. Relief valve opens at a
pressure differential of approximately 600 psi

between suction and discharge. 38GC units prior to
serial number A-900001 were equipped with low
pressurestat located on suction service valve. Low
pressurestat settings are: cutout, 31 ±4 psig;

cut-in, 6 0 - 1 - 1 5 psig, -0 psig. All units between

serial no. A-900001 and C-962493 not equipped
with low-pressure switch. 38GC units (using 06R

compressors) from serial no. C-962493 are equipped

with liquid line low pressurestat. Settings are:

cutout, 27 ± 4 psig; cut-in, 60 -t- 15 psig, -0 psig.

Table 6 — Service Data

COND UNIT

38GC

38GC,GF

38GF

101

102

103

104

145

105

' - ' "1

6-6

106

R-22 CHG* (Ib-oz)

GC

2-7

3-2

4-6

4-7 4-13

5-6

GF

-

3-10

•y* >

4-14

5-2 c-3

6-9

7-8

8-3

COMPRESSOR

38GC

38GC

38 GC

06 R

06RC OBGC

06 R

06 R

06 R

1-Phase

400224

400214

.1

C3526CB

' ' '

39 26 CE -105 564

C5425CV

C5425CV

C7022CV

208 V

_

_

F3522CW

F3922CW i -

F5422CW

F5422CW

F7022CW

3-Phase

230 V

_

G3522CW

G3922CV.. ••

G5422CV;

G5422CV;

G7022CW

460 V

__

_

H3922CV.

H5422CVV

H5422CV-;

H7022CW

Type Start (1-Ph)

PSC

PSC

CSRt

CSR ...........CSS

CSR

CSR

CSR

Oil Recharge (oz)

21

40

36

' L..^...................

36 46

72

72

72

COND FAN

Propel ler Tvoe — D

i

rect Drive

Rpm

GC

1650

1650

1050

1050 'ssr

1050

825

-

Rpm

GF

__

1050

1-OSQ j 1050

í. ■

1050 1050

1050

825

825

Diam (in.)

GC

16

16

18

is

20 CO

20

22

-

Diam (in.)

GF

-

18

18

- ' ta

20 . 20

20

22

.

Cim

2300

2400

. 2-100

2200

¡4^

2900

2900

3900

3900

3860102310,103310,104310;

38GF102310,103310,104310

38GC,GF103320

CSR

— Capacitor Start

PSC

— Permanent Split Capacitor

*Factory

refrigerant

charge

adequate

when

condensing

units are connected to

Carrier approved evaporators

with up to 25 ft of tubing See Refrigerant charging

for details

t38GC103 unitsare permanent split-capacitor type