2.4

Operating modes

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-8

2.4.2

Sequential muting

Sequential muting

2-

2.4.2.1

Position of the muting sensors

Position of the muting sensors

2-

Muting_Betriebsarten_sequenzielles Muting-Anordnung der Muting-Sensoren

The distance between the muting sensors MS1 and MS2 / MS3 and

MS4 should be as large as possible.

Vehicle length W must be greater than the distance between MS1 and

MS3 or MS2 and MS4 (W > A and W > B).

MS2 and MS3 must be positioned as close as possible in front of/be-

hind the AOPD.