2.4
Operating modes
2
Muting
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-8
2.4.2
Sequential muting
Sequential muting
2-
2.4.2.1
Position of the muting sensors
Position of the muting sensors
2-
Muting_Betriebsarten_sequenzielles Muting-Anordnung der Muting-Sensoren
The distance between the muting sensors MS1 and MS2 / MS3 and
MS4 should be as large as possible.
Vehicle length W must be greater than the distance between MS1 and
MS3 or MS2 and MS4 (W > A and W > B).
MS2 and MS3 must be positioned as close as possible in front of/be-
hind the AOPD.
MS1
MS2
MS3 MS4
AOPD
AOPD
W
A
B