3 connecting the base unit and expansion modules, Connecting the base unit and expansion modules, Installation – Pilz PNOZ m B0 User Manual

Page 16

Advertising
background image

Installation

Operating Manual PNOZ m B0
1002660­EN­03

16

INFORMATION

Please note that at the stated minimum distance, it will be difficult to swap
the chip card from above. If you cannot leave a greater distance, remove
the unit from the mounting rail to swap the chip card.

5.3

Connecting the base unit and expansion modules

Please refer to the document "System Expansion" for details of the number of modules that
can be connected to the base unit and the module types.

The modules are linked via jumpers.

}

Remove the terminator on the side of the base unit and on the expansion module.

}

Install the base unit and expansion modules on the mounting rail and connect the units
using the jumper supplied

}

Fit the terminator to the unconnected interfaces on the base unit and expansion mod­
ule.

Terminator

Terminator

IM0 IM1 IM2

I6

I5

I4

IM3

I7

I8

I10

I14

I13

I12

I11

I15

X3

X1

X4

X2

PNOZ mm0.1p

T0

T1

T2

O2

O1

O0

T3

O3

IM16 IM17 IM18

0 V

A2

A1

IM19

24 V

M20

M21

M22

M23

Jumper

CAUTION!

Only connect the base unit and expansion modules when the supply voltage
is switched off.

Advertising