3 safety, 1 intended use, 2 safety regulations – Pilz PSSu H PLC1 FS SN SD User Manual
Page 9: 1 use of qualified personnel, Section 3, Safety, Intended use, Safety regulations, Use of qualified personnel, 3safety
Safety
Operating Manual PSSu H PLC1 FS SN SD(T)(R)
21939EN10
9
3
Safety
3.1
Intended use
The module is suitable for use in safety and nonsafetyrelated applications, with and
without SafetyNET p.
The modules PSSu H PLC1 FS SN SD and PSSu H PLC1 FS SN SDT may be used as a
safety component in accordance with the Lifts Directive 95/16/EC, EN 811, EN 812 and
EN 1151.
The programmable safety system should be installed in a protected environment that meets
at least the requirements of pollution degree 2. Example: Protected inside space or control
cabinet with protection class IP54 and corresponding air conditioning.
The module PSSu H PLC1 FS SN SDT is suitable for use where there are increased envir
onmental requirements (see Technical Details).
The module PSSu H PLC1 FS SN SDR is suitable for use where there are increased en
vironmental requirements demanded by railway applications (see Technical Details).
Intended use includes making the electrical installation EMCcompliant. Please refer to the
guidelines stated in the "PSSuniversal Installation Manual". The module is designed for use
in an industrial environment. It is not suitable for use in a domestic environment, as this can
lead to interference.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the module
}
Use of the module outside the areas described in this manual
}
Any use of the module that is not in accordance with the technical details.
NOTICE
Always use the latest version of PAS4000 for programming the head mod
– Base type and Ttype:
at least version 1.3.1.
– Rtype:
at least version 1.5.0
3.2
Safety regulations
3.2.1
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.