42

Insertion Test

This option performs a device-insertion check of the chip in

the socket. The insertion check includes poor pin contact, pin

count mismatch (the pin count of the chip designated in the

software does not match the pin count of the actual chip in the

socket), device in wrong position, device upside-down;

short-circuit between pins, and chip damage. Result is

displayed at the socket

s LED’s.

Device ID Check

This option performs a device signature and manufacturer

match test. With the chip selected and plugged into the socket,

DATAMAN-48XP checks the device ID and displays the

results of each check on the LED display.

Verify Passes

Checking this option will instruct the DATAMAN-48XP to

perform device verification with the buffer data when

programming is complete. When verify passes is enabled, one

of the three verify options (as described below) must be set.

Verifying Options

The following three options are available for verification of

data retention following programming: verify twice with V

cc

±±±±5%, verify twice with V

cc

±±±±10% , and verify once with V

cc

.

These options will only be enabled if the ‘Verify passes’

option (see above) is enabled.

(

) Twice V

cc

±±±±5%

When this option is selected, the DATAMAN-48XP will do

two verify passes on the device: one using V

cc

+5%, the other

V

cc

-5%.

Advertising