Specifications

A-2

TM-F2OP-C1XN-01

Electrical Specifications

These specifications are warranted over a temperature range of 0 °C to
50 °C.

Nominal ambient temperature assumed is 25 °C.

Nominal line voltage is 208 Vac, 60 Hz.

See Table A-1 and Table A-2 for maximum values for model-dependent
specifications.

Specifications are subject to change without notice.

Table A-1 Specifications for 7.5 V to 40 V Models

Models

7.5-300

12-220

20-130

33-85

40-70

Output Ratings:

Output Voltage

a

Output Current

b

Output Power

0-7.5 V
0-300 A
2250 W

0-12 V
0-220 A
2640 W

0-20 V
0-130 A
2600 W

0-33 V
0-85 A
2805 W

0-40 V
0-70 A
2800 W

Line Regulation:

c

Voltage

(0.01% of Vmax +

2 mV)
Current (0.01% of Imax + 2 mA)

2.75 mV
32 mA

3.2 mV
24 mA

4 mV
15 mA

5.3 mV
10.5 mA

6 mV
9 mA

Load Regulation:

d

Voltage (0.02% of Vmax +
5 mV)
Current (0.02% of Imax + 5 mA)

6.5 mV
65 mA

7.4 mV
49 mA

9 mV
31 mA

11.6 mV
22 mA

13 mV
19 mA

Meter Accuracy:

Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)

0.09 V
4 A

0.13 V
2.3 A

0.3 V
1.4 A

0.43 V
0.95 A

0.5 V
0.8 A

Output Noise (0-20 MHz):

Voltage (p-p)

100 mV

100 mV

100 mV

100 mV

150 mV

Output Ripple (rms):

Voltage
Current

e

10 mV
1600 mA

10 mV
1200 mA

10 mV
400 mA

15 mV
300 mA

15 mV
200 mA

Drift (30 minutes):

f

Voltage (0.07% of Vmax)
Current (0.7% of Imax)

For Resistive Programming:

Voltage (0.6% of Vmax)
Current (0.6% of Imax)

3.75 mV
2100 mA

45 mV
1800 mA

6 mV
1540 mA

72 mV
1320 mA

10 mV
910 mA

120 mV
780 mA

16.5 mV
595 mA

198 mV
510 mA

20 mV
490 mA

240 mV
420 mA

Advertising