4.3.8.3 Display Faults

Figure 30 depicts an 8-port switch example of a

Display Faults report. For switches of

16- and 24-ports, the applicable number of ports would be displayed. Except for the

refresh option, this screen is read-only. The current fault report is displayed when the

screen first appears. While on screen, this report is static; it will only be updated if the

refresh option is selected.

Figure 30 — Display Faults

After relay activation is noted, the fault should be corrected. If

No Link monitoring is in

force, this will require restoration of a broken link or repair of the defective device to

which the switch is connected. On the other hand, if

Link Present monitoring is in use,

removing the offending cable or end device will be required.