Lan leds, Power supply unit led, Lan leds power supply unit led – Grass Valley FT Server User Manual
Page 63
Action
Possible Cause
Meaning
Name
At first, confirm
whether event log is
registered by
Temperature sensor.
Replace CPU/IO
module.
There is a possibility of
sensor failure.
Cooling problem (Fan
Failure)
Processor placement
Processor failure
CPU/IO Module failure
Amber LED illuminates
when temperature in
CPU/IO module
becomes abnormal.
TEMP (Abnormal
temperature LED
At first, confirm
whether event log is
registered by FAN
sensor.
Is fan working?
Is there a clog of
module?
Replace CPU/IO
module.
There is a possibility of
sensor failure.
FAN failure
CPU/IO Module failure
Amber LED illuminates
when failure occurs on
the cooling fan of
CPU/IO module.
FAN (FAN error LED)
LAN LEDs
The LED indicators on the Ethernet LAN connectors are described below.
•
LINK/ACT LED:
The LINK/ACT LED shows the status of a standard network port. It is green if power is supplied
to the main unit and hub and they are connected correctly (LINK). It blinks green while the
network port sends or receives data (ACT).
When the LED does not illuminate during LINK, check the condition and connection of network
cables. If there is nothing wrong with the cables, a defect is suspected in the network (LAN)
controller. In this case, contact Customer Service.
•
Speed LED:
This LED indicates the network interface of the communication mode used by a network port.
1000BASE-T and 100BASE-TX are the supported LAN port types. When this LED illuminates
in amber, the port is operating on 1000BASE-T; when in green, 100BASE-TX; and when not
illuminate, 10BASE-T.
Power supply unit LED
When the power supply unit has a failure, the amber LED light will light. There are two power
supplies per system.
20131220
FT Server Instruction Manual
63
Servicing the FT Server