Installing a hard disk drive – Grass Valley FT Server User Manual
Page 88
5. Slowly close the lever. When the lever is locked, you will hear a clicking sound. Check that the
hook of the lever is engaged with the frame.
6. Press the POWER switch to power on.
Original drives installed into a replacement CPU/IO module should require no configuration.
7. Install the front bezel.
Installing a hard disk drive
Follow the procedure below to install hard disk drives that have been removed from a faulty CPU/IO
module and are being installed in the replacement module from the factory.
1. Shut down the OS. The system turns off automatically.
2. Remove the front bezel.
NOTE: When installing hard disk drives into a replacement CPU/IO module, be sure to put
the hard disk drive into the same slot that you marked on it when you removed it from the
failed CPU/IO module.
3. Unlock the hard disk drive.
88
FT Server Instruction Manual
20131220
Servicing the FT Server