Sequence for “Automatic reference mark traverse” (pressing the machine START key).
MP1350.x = 1

Press the machine START key

Trip dog

"Reference end position"

closed?

Machine moves

in direction from

MP1320.x

Machine moves in

inverted direction from

MP1320.x

Reference mark is passed over

Is the machine

outside the software

limit switch range?

Machine moves to

software limit switch

Machine stops

No

Yes

Yes

No

Yes

No

Trip dog

"Reference end position"

is closed before reference

mark is passed over