Machine parameter list, 2 machine parameter list – HEIDENHAIN TNC 122 Technical Manual User Manual
Page 39
38
TNC 122
11 Machine Parameters
4/97
11.2 Machine Parameter List
Machine
Parameter
Function and input
Input value
MP 31
Monitoring of encoder signal amplitude
Input values: 0 to 7
Bit 0 Axis X
+0
inactive
+1
active
Bit 1
Axis Y
+0
inactive
+2
active
Bit 2
Axis Z
+0
inactive
+4
active
MP 40
Displayed axes
Input values: 0 to 7
Bit 0 Axis X
+0
not displayed
+1
displayed
Bit 1
Axis Y
+0
not displayed
+2
displayed
Bit 2
Axis Z
+0
not displayed
+4
displayed
MP70
Analog output bipolar or unipolar
Input values: 0 or 2
0 = bipolar
1 = unipolar (ensure that MP1040 = 0!)
traversing the end position outputs 0 V
2 = unipolar, traversing the end position inverts
the nominal-value voltage
MP80
Analog voltage source for rapid traverse from
the control or from external source
Input values: 0 to 2
0 =
reserved
1 = analog voltage from external source
2 = analog voltage from control
(Position control loop closed)
MP110.0-2
Assignment of encoder inputs to the machine
axes
Input values: 0 to 2
0 = encoder input X1
1 = encoder input X2
2 = encoder input X3
MP210
Counting direction of encoder signals
Input values: 0 to 7
Bit 0
Axis X
+0 = positive
+1 = negative
Bit 1
Axis Y
+0 = positive
+2 = negative
Bit 2
Axis Z
+0 = positive
+4 = negative
MP330.0-2
Grating period
Input values: 4, 10, 20, 40, 100, 200 [µm]