11 Machine Parameters

4/97

Machine
Parameter

Function and input

Input value

MP4220

Setting a number in the PLC word range
W960 to W968
Input values: 0 to 65535

MP4220.0

1 = bipolar without SE functions
2 = unipolar without SE functions
5 = bipolar with SE functions
6 = unipolar with SE functions
12 = erosion with SE functions

MP4220.1

0 =

Static M output

+1 =

M03/M05 impulse or

M16/M17 impulse

+2 =

M04/M05 impulse or

M18/M19 impulse

+4 =

M08/M09 impulse

+8 =

M20/M21 impulse

+16 =

M22/M23 impulse

+32 =

M24/M25 impulse

+64 =

M26/M27 impulse

+128 =

M28/M29 impulse

+256 =

M32/M33 impulse

MP4220.2

0 =

M acknowledgment to
I15

+1 =

M03 automatic

+2 =

M04 automatic

+4 =

M8/M9 automatic

+8 =

M16/M17 automatic

+16 =

M18/M19 automatic

+32 =

M20/M21 automatic

+64 =

M22/M23 automatic

+128 =

M24/M25 automatic

+256 =

M26/M27 automatic

+512 =

M28/M29 automatic

+1024 = M32/M33 automatic
+2048 = M00/M02/M05/M30

automatic

MP4220.3

If potentiometer closed, NC stop feed rate
potentiometer minimum

Minimum potentiometer feed
rate 0%

MP4220.4

If potentiometer closed, NC stop feed rate
potentiometer maximum

Active minimum potentiometer
feed rate 0%

A change to the machine parameters MP4220.x only becomes active after a power
interruption.