I - 2 Working with POSITIP – First Steps

22

Operating Instructions

POSITIP 855

Probing functions for datum setting

The POSITIP's probing functions enable you to set datum points

with a HEIDENHAIN KT Edge Finder. The probing functions are

also available when you are using a tool instead of an edge finder.

Datum setting with the edge finder

It is particularly easy to set datum points with a HEIDENHAIN

KT Edge Finder. The following probing functions are available:

• Workpiece edge as datum:

Edge

• Centerline between two workpiece edges:

Centerline

• Center of a hole or cylinder:

Circle Center

With Circle Center, the hole must be in a main plane.

The three main planes are formed by the axes X / Y, Y / Z

and Z / X.

The HEIDENHAIN KT 120 Edge Finder can only be

used with electrically conductive workpieces.

Preparation: Enter the stylus diameter and select the datum

ä Press MOD and go to the soft key row containing the soft key

Edge Finder.

ä Select the user parameter

Edge Finder

.

ä Enter the diameter of the edge finder stylus and confirm with

ENT.

ä Select the user parameter

Datum

.

ä Enter the number of the desired datum and confirm with ENT.

ä Press MOD again.

The number of the selected datum is now shown at the lower

right of the screen.

In all probing functions, POSITIP takes into account the entered

stylus diameter.

For more information on user parameters, see chapter I - 7.

Exiting the probing function

While the probing function is active, POSITIP displays the soft key

Escape

. Choose this soft key to return to the opening state of the

selected probing function.

Fig. 19: The HEIDENHAIN KT Edge Finder