II - 2 Operating Parameters

88

Technical Information

POSITIP 855

11

6

1

12

7

2

13

8

3

14

9

4

15

10

5

User parameters

The machine manufacturer has defined certain operating

parameters as user parameters. You can change the settings of

user parameters without having to enter the code number (see

Operating Instructions section, chapter I - 7).

Position of user parameters in the menu

In operating parameters P100 to P122, the machine manufacturer

defines how the user parameters are arranged in the soft keys.

Field 15 is reserved for the

Code Number

soft key.

If a parameter is assigned field number 0, it will not appear in the

user parameter menu.

Operating User parameter

Standard

parameter designation

*)

field

P 100

mm / inch (P 1)

4

........

P 101.1

Radius / diameter 1 (P 3.1) 0

........

P 101.2

Radius / diameter 2 (P 3.2) 0

........

P 101.3

Radius / diameter 3 (P 3.3) 0

........

P 101.4

Radius / diameter 4 (P 3.4) 0

........

P 103

Angle format (P 8)

5

........

P 104

Scaling factor ON/OFF (P 11) 10

........

P 105.1

Scaling factor 1 (P 12.1)

6

........

P 105.2

Scaling factor 2 (P 12.2)

7

........

P 105.3

Scaling factor 3 (P 12.3)

8

........

P 105.4

Scaling factor 4 (P 12.4)

9

........

P 109

Edge finder (P 25, P 26)

1

........

P 112

RS-232-C baud rate (P 50)

11

.......

P 113

RS-232-C line feeds (P 51)

12

.......

P 120

Tool table

2

........

P 122

Datum table

3

........

*)

The corresponding operating parameters are indicated in

parentheses.

Fig. 40: Fields for user parameters