II - 2 Operating Parameters
88
Technical Information
POSITIP 855
11
6
1
12
7
2
13
8
3
14
9
4
15
10
5
User parameters
The machine manufacturer has defined certain operating
parameters as user parameters. You can change the settings of
user parameters without having to enter the code number (see
Operating Instructions section, chapter I - 7).
Position of user parameters in the menu
In operating parameters P100 to P122, the machine manufacturer
defines how the user parameters are arranged in the soft keys.
Field 15 is reserved for the
Code Number
soft key.
If a parameter is assigned field number 0, it will not appear in the
user parameter menu.
Operating User parameter
Standard
parameter designation
*)
field
P 100
mm / inch (P 1)
4
........
P 101.1
Radius / diameter 1 (P 3.1) 0
........
P 101.2
Radius / diameter 2 (P 3.2) 0
........
P 101.3
Radius / diameter 3 (P 3.3) 0
........
P 101.4
Radius / diameter 4 (P 3.4) 0
........
P 103
Angle format (P 8)
5
........
P 104
Scaling factor ON/OFF (P 11) 10
........
P 105.1
Scaling factor 1 (P 12.1)
6
........
P 105.2
Scaling factor 2 (P 12.2)
7
........
P 105.3
Scaling factor 3 (P 12.3)
8
........
P 105.4
Scaling factor 4 (P 12.4)
9
........
P 109
Edge finder (P 25, P 26)
1
........
P 112
RS-232-C baud rate (P 50)
11
.......
P 113
RS-232-C line feeds (P 51)
12
.......
P 120
Tool table
2
........
P 122
Datum table
3
........
*)
The corresponding operating parameters are indicated in
parentheses.
Fig. 40: Fields for user parameters