Encoder commissioning example, DPV0

59

Selecting the DPV0 Slave
To select the encoder click on the “PROFIBUS Encoder” icon in

the map structure on the right side of the window. Use “drag-

and-drop” to add the encoder on the BUS, upper left view.

When dropping the encoder on the BUS a PROFIBUS address

must be assigned, naturally this address must be the same as

assigned on the hardware address switches on the back of the

encoder. See chapter 3.1.1.

Configuration of DPV0 Slave
To configure the encoder for 25-bit position value plus

velocity data choose the “Encoder Class 2 32-bit velocity”

configuration option in the map structure. Add the chosen

configuration by “drag-and-drop” to the configuration

window in lower left view.