1-1.Check List when replacing ∑ with ∑-Ⅴ

Category Item

Where to check

Checked

<Confirmation of main body installation dimension/position>

Please confirm installation dimensions of the motor in-use and

machine in-use.

Inside low diameter

Mounting hole pitch

Mounting hole diameter

Axis diameter

Axis shape (straight, key, center tap, and taper)

Main Body

< Confirmation of special specification >

Please confirm whether the motor you are using now is a special

type.

Please confirm the specification with the delivery specifications if

you are using a special type.

Voltage

Correspondence of AC100V specification>

Selected the both servo motor and servo amplifier which were for

100V when using the AC100V power supply in ∑-I. However, only

AC200V motor is available in the ∑-V. Select the proper servo

amplifier when using AC100V power supply.

Motor

Cable

Confirmation of wiring direction>

Please confirm how to wire, and also confirm that the machine has no

interference.

< Confirmation of main body mounting position >

Please confirm the size (W・H・D) and the mounting hole position of

the servo amplifier in-use.

Main Body

< Confirmation of special specification >

Please confirm whether the servo amplifier in-use does not have your

own NP, and product shape, and also confirm that any special

processes etc. are not done by referring the delivery specification.

Servo

Amplifier

Hardware

Main

Circuit

< Confirmation of wiring >

Changed to the connector connection from the terminal block for

models of 1.5kW or less.

The main circuit connector, terminal block position, terminal marking

and order are different between the servo amplifier in-use and the

replacement servo amplifier.

Please consider the substitution of extension of wiring when there is

not enough room in wiring.