10-MAINTENANCE AND CLEANING

END-OF-SEASON SHUTDOWN

At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a vacuum

cleaner that has a long pipe.

The appliance must be disconnected from the mains when it is not used. It is recommended to remove the power cable for

additional safety, especially in the presence of children.

The service fuse may have to be replaced if the control panel display does not go on when the product is next switched on by pressing the

main switch on its side.

There is a fuse compartment on the side of the product, under the power socket. After having disconnected the plug from the socket, use

a screwdriver to open the cover of the fuse compartment and if necessary, replace them (3.15 A delayed).

CHECKING THE INTERNAL COMPONENTS

ATTENTION!

The internal electromechanical components must only be checked by qualified personnel whose technical expertise

includes combustion and electricity.

It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and

functional verification of the internal components. The following is a summary of the necessary checks and/or maintenance for the

product to work correctly.

PARTS/INTERVAL

1 DAY

2-3 DAYS

30 DAYS

60-90 DAYS

1 YEAR

Brazier

·

Ash collection compartment

·

Ash pan

·

Glass

·

Lower exchanger

·

Complete exchanger

·

Smoke duct

·

Door gasket

·

Air filter

·

Product

·