10-MAINTENANCE AND CLEANING
END-OF-SEASON SHUTDOWN
At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a vacuum
cleaner that has a long pipe.
The appliance must be disconnected from the mains when it is not used. It is recommended to remove the power cable for
additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not go on when the product is next switched on by pressing the
main switch on its side.
There is a fuse compartment on the side of the product, under the power socket. After having disconnected the plug from the socket, use
a screwdriver to open the cover of the fuse compartment and if necessary, replace them (3.15 A delayed).
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and
functional verification of the internal components. The following is a summary of the necessary checks and/or maintenance for the
product to work correctly.
PARTS/INTERVAL
1 DAY
2-3 DAYS
30 DAYS
60-90 DAYS
1 YEAR
Brazier
·
Ash collection compartment
·
Ash pan
·
Glass
·
Lower exchanger
·
Complete exchanger
·
Smoke duct
·
Door gasket
·
Air filter
·
Product
·
Remote control battery
·