Twisted pair construction.
•
Applicable hazardous area requirements, if the core processor is installed in a
hazardous area.
•
Wire gauge appropriate for the cable length between the core processor and the
transmitter.
Wire gauge
Table 3-1:
Wire gauge
Maximum cable length
VDC 22 AWG (0.35 mm
2
)
300 ft (90 m)
VDC 20 AWG (0.5 mm
2
)
500 ft (150 m)
VDC 18 AWG (0.8 mm
2
)
1000 ft (300 m)
RS-485 22 AWG (0.35 mm
2
) or larger
1000 ft (300 m)
3.3
Wire the transmitter to the sensor
1.
Connect the cable to the core processor as described in the sensor documentation.
2.
Feed the wires from the sensor through the conduit opening.
3.
Connect wires to the appropriate terminals on the mating connector.
Important
Never ground the shield, braid, or drain wire(s) at the transmitter.
Tip
You may find it easier to unplug the mating connector to connect the wires. If you do so,
remember to firmly reseat the mating connector and tighten the mating connector screws so
that the mating connector cannot accidentally come loose.
Mounting and sensor wiring for 4-wire remote installations
22
Micro Motion
®
Model 1700 and 2700