Emerson MICRO MOTION 1700 User Manual
Page 97
Advertising
![background image](/manuals/84525/97/background.png)
Safe area frequency output/discrete output load resistance values
Figure 8-12:
10000
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
5
7
9
11
13
15
17
19
21
23
OPERATING REGION
Supply voltage VDC (Volts)
External pull-up resistor R
load
range
(Ohms)
R
max
= (V
supply
– 4)/0.003
Rmin = (Vsupply – 25)/0.006
Min. 100 W for supply voltage less than 25.6 Volts
25
27
29
I/O wiring for Model 1700 and Model 2700 transmitters with intrinsically safe outputs
Installation Manual