Honeywell HC900 User Manual
Page 69
Revision 10
HC900 Hybrid Controller Communications User Guide
61
12/07
Fixed
Address
(hex)
Fixed
Register
(decimal)
Parameter
Access
Notes
1F10
7953
Jog Segment
R/W
Floating Point
Writing to this register is only permissible in
the reset or ready mode
1F12
7955
Loop Start
R/W
Floating Point
0 indicates no loop.
Writing to this register is only permissible in
the reset or ready mode
1F14
7957
Loop End
R/W
Floating Point
0 indicates no loop.
Writing to this register is only permissible in
the reset or ready mode
1F16
7959
Repeats
R/W
Floating Point
0 indicates loop forever.
Writing to this register is only permissible in
the reset or ready mode
1F3A
7995
Time Units**
R/W
Bit Packed
Bit 0:
Reserved
1: minutes
2:
hours
3-15: Unused
1F3B
7996
Ramp Units**
R/W
Bit Packed
Bit
0:
0:Time; 1:Rate
Bit 1-15:
Unused
Writing to this register is only permissible in
the reset or ready mode
1F3C
7997
Guaranteed Soak Type **
R/W
Bit Packed
For selection of Soak (or Hold) guarantee –
Per Segment (requiring selection per
segment in a table)
Bit
0: per segment
1: all soaks
2: all segments
3-15:
Unused
None if none of the bits is set
Writing to this register is only permissible in
the reset or ready mode