Weight and physical dimensions, Facility requirements, 23 san switch physical dimensions – IBM AA-RWF3A-TE User Manual

Page 134: 24 facility requirements

Advertising
background image

Weight and physical dimensions

Table 23

lists physical properties for the SAN Switches.

Table 23 SAN Switch physical dimensions

4/8 and 4/16

SAN Switches

4/32 SAN Switch

4/64 SAN Switch

4/32B SAN Switch

Height

4.29 cm (1.69

in)

42.44 mm (1.67 in)

2U or 8.6 cm (3.4 in)

1U or 43.5 mm

(1.71 inches)

Width

42.85 cm

(16.87 in)

429 mm (16.89 in)

42.8 cm (16.8 in)

428.75 mm (16.88

inches)

Depth

30.734 cm

(12.10 in)

584.2 mm (23.0 in)

61 cm (24 in)

264 mm (10.39

inches)

Weight

4.0 kg (8.8 lb)

10.16 kg (22.4 lb)
with two power supplies,

three fan assemblies,

and zero SFPs installed

13.7 kg (30.2 lb)
with two power

supplies, three fan

assemblies, and zero

SFPs installed

4.9 kg (10.8 lb)
with two power

supplies/fan

assemblies and zero

SFPs installed

Facility requirements

To ensure correct operation of the switch, the facility where the switch is in use must

meet the requirements shown in

Table 24

.

Table 24 Facility requirements

Type

Requirements

Electrical

Primary AC input: 100–240 VAC, 2.0 A, 47–63 Hz; switch autosenses input

voltage.
Adequate supply circuit, line fusing, and wire size, as specified by the electrical

rating on the switch nameplate.
Circuit protected by a circuit breaker and grounded in accordance with local

electrical codes.

Thermal

4/8, 4/16, 4/64 and 4/32B SAN Switches: A minimum airflow of 47 cubic

ft/minute available in the immediate vicinity of the switch.
4/32 SAN Switch: A minimum airflow of 24 cubic ft/minute available in the

immediate vicinity of the switch.
Ambient air temperature not exceeding 40 ºC (104 ºF) while the switch is operating.

Cabinet (when

rack mounted)

4/8, 4/16 4/32 and 4/32B SAN Switches:
One rack unit in a 48.3 cm (19 in) cabinet.

134

SAN Switch technical specifications

Advertising