3.

At the Fabric Parameters prompt, enter y and press Enter:

Fabric Parameters (yes, y, no, n):

(no)

y

4.

Enter a unique domain ID, such as the domain ID used by the previous switch, if

it is still available:

Domain:

(1..239) [1]

3

5.

Respond to the remaining prompts or press Ctrl+D to accept the default settings.

6.

Issue the switchenable command to re-enable the switch.

7.

Optional: Specify any custom status policies:
a. Issue the switchstatuspolicyset command. This command sets the

policy parameters that determine the overall switch status.

b. Customize the status policies.

To deactivate the alarm for a particular policy, enter 0 at the prompt for that policy.

Install the SFP transceivers

The SAN Switch does not ship with SFPs. For a list of supported SFPs, see

Table

2

on page 33.

The ports selected for use in trunking groups must meet specific requirements. For a list of

these requirements, see the ISL Trunking chapter in the Fabric OS administrator’s guide.
To install the SFP transceivers:

1.

Position the transceiver so that it is oriented correctly and insert it into a port until the

latching mechanism clicks. The transceivers are keyed to ensure correct orientation.

If the transceiver does not install easily, make sure it is oriented correctly.
For instructions specific to the transceiver you are using, see the transceiver

manufacturer’s documentation.

2.

Repeat

step 1

for the remaining ports, as required.

SAN Switch installation guide