Items required, Procedure, 19 4/32 san switch fan status led behavior – IBM AA-RWF3A-TE User Manual

Page 97

Advertising
background image

Table 19 4/32 SAN Switch Fan Status LED behavior

LED color

Meaning

Corrective action

No light

Fan assembly is not receiving power. Verify that the fan assembly is seated in the

switch.

Steady green

Fan assembly is operating normally. No action required.

Steady amber

for more than 5

seconds

Fan fault for one of the following

reasons:
One or more of the fans in the fan

assembly has failed.
The fan FRU was disabled by the

user.

Verify that the fan FRU is enabled. If the

fan FRU is enabled, it is faulty and should

be replaced.

Items required

Replacing a 4/32 SAN Switch fan assembly takes approximately two minutes and

requires the following items:

New fan assembly

Phillips #1 screwdriver

Procedure

To replace a fan assembly in a 4/32 SAN Switch:

1.

Unscrew the captive screw on the fan assembly using a Phillips screwdriver.

2.

Remove the fan assembly from the chassis by pulling its handle out and away

from the chassis.

3.

Orient the new fan assembly as shown in

Figure 32

, with the captive screw on

the right.

4.

Gently push the new fan assembly into the chassis until it is firmly seated.

5.

Secure the fan assembly to the chassis by tightening the captive screw.

SAN Switch installation guide