6.

Identify the screw holes to be used on the inner rails designed for the switch:
• To attach the inner rails to the SAN Switch 2/32 use the screw holes

marked 32.

• To attach the inner rails to the 4/8, /16 and 4/32B SAN Switches, use five

screw holes marked 8, and the plenum requires one screw hole marked 8

and one screw hole marked 16, as shown in

Figure 15

on page 48.

• To attach the inner rails to the 4/32 or 4/64 SAN Switch, use the screw

holes marked 16, as shown in

Figure 16

on page 48.

7.

Assemble the two inner rails to the device using the appropriate number of screws

(see

Table 5

):

• For the 4/8 and 4/16 SAN Switches, secure each inner rail (one on each

side) to the switch using seven #8-32 x 5/16-inch Phillips pan-head SEMS

screws, as shown in

Figure 15

on page 48.

• For the 4/32 SAN Switch, secure each inner rail (one on each side) to the

switch using five #8-32 x 5/16-inch Phillips pan-head screws with thread

lock, as shown in

Figure 16

on page 48.

• For the 4/64 SAN Switch, secure each inner rail (one on each side) to

the switch using five #8-32 x 5/16-inch Phillips pan-head SEMS screws,

as shown in

Figure 16

on page 48.

• For the 4/32B SAN Switch, secure each inner rail (one on each side)

to the switch using six #8-32 x 5/16-inch Phillips pan-head screws with

thread lock.

NOTE:

For integration in a cabinet, tighten the #8-32 x 5/16-inch Phillips

pan-head SEMS screws and torque between 6 and 8 inch-pounds.

SAN Switch installation guide