6.1 Power-up Sequence and
Basic Use of the Administrator Functions


NOTE: When the system is first turned on, it may take as long as 90 seconds before the front
panel display will show any activity, and before the system will 'wake up'. Total boot-up time is
generally about 3 minutes.

When the SCS3230 is first installed and powered up, it must be configured through the serial
terminal port. Connect the terminal port to a terminal device or computer using a terminal
emulation program. After the network interface has been configured, the administration login
may also be reached via telnet. All the functions available from a local serial connection (with
the exception of

BACKUP and RESTORE) are also available through telnet by connecting to port

5000 of a ConsoleServer’s network IP address.

The serial terminal will display the following text at power-up:


ConsoleServer3200 Boot V1.76

Copyright 2000 by Lightwave Communications, Inc. All rights reserved.
Identify Flash

Flash ID OK

Verifying Flash Image
Starting system

Lightwave Communications, Inc. ConsoleServer3200
Please wait...system initializing

Checking non-volatile memory...
2048

Start checking and reading stored data

Reading User Start up .........

LCI3200>>

The power-on self-test may be skipped by pressing

<ESC> <ESC> or <CTRL>+C, but

the SCS3230 should be allowed to complete the POST if possible (this check usually
takes about three minutes). This information is not available on a network connection,
as it is not possible to connect to the ConsoleServer via telnet until the power-on self-
test is complete. At the completion of the power-up sequence, the administrator is
logged out, as indicated by the

LCI3200>> prompt. Some commands may be used

from this prompt, but most are available only when logged in.

NOTE: The administrator may define the system prompt using the

PROMPT command (see

section 6.11), but the system default prompt (

LCI3200>>) is used in this guide for clarity.