C O M M A N D R E F E R E N C E

LDX-3232 Device-Dependent Commands

04_06

LDX-3232

39

C H A P T E R

4

LDX-3232 Device-Dependent Commands

This section contains all of the device-dependent commands for the LDX-3232
High Compliance Current Source, listed in alphabetical order. Sub-sections for
each path are presented, listing the commands that are legal for that path. See
Figure 3.1 for command path tree structure.

Figure 4.1 Command Description Format

Command Path:Name
Required letters are shown in
upper case; lower case letters
are optional.

Front Panel/

A solid box means the command
can be executed in that mode.
Command mnemonics in front
panel (local) mode may vary.

Command Description

Syntax Diagram
(For Remote Commands)

Parameters
Tells what parameters are
expected, and their type.

An <nrf value> refers to a
flexible numeric notation
(IEEE-488.2). Integer,
exponential, or floating point
may be used with the decimal
radix. Alternate radices may be
selected in remote operation.

Points of Interest
Has special information
about the command.

Examples
Shows typical statements
using the command.

Front Panel

Remote

LASer:LIMit:I

limit value.

SYNTAX DIAGRAM

<white

space>

< nrf

value >

:

:

:

LAS

LIM

PARAMETERS

An <nrf value> that represents the LASER limit

current, in mA.

POINTS OF

INTEREST

The current limit is in effect in all modes of

operation of the laser output.

In local operation, the limit current is entered

by selecting the LIM I parameter, pressing and

holding in the (PARAMETER) SET switch,

adjusting the ADJUST knob until the desired value

is displayed, and then releasing the SET switch.

EXAMPLES

Remote Execution

I2

"Las:Lim:I2 100" - action: the LASER current limit

is set to 100.0 mA.

"LAS:LIM:I4 3000" - action: the LASER current limit

is set to 3000.0 mA.

1

The LASer:LIMit:I2 command sets the laser current

Advertising