C O M M A N D R E F E R E N C E

LDX-3232 Device-Dependent Command Reference

04_06

LDX-3232

41

C H A P T E R

4

The ERRors? query returns a list of command and device errors that have occurred
since the last query. These errors are notated by a number that corresponds to the type
of error that occurred. See Chapter 3 for information regarding error handling.

Syntax Diagram

Parameters

None.

Notes

The response data will be a list of the current errors. The errors are represented by
numbers and are separated by commas. A response of 0 indicates that no errors were
reported. The response data is sent as character data. Up to 10 error codes are stored
between error queries.

Examples

"ERR?" -response: 0, means no errors reported.

"Errors?" -response: 201, means that the <PROGRAM DATA> (parameter) value out of
range error was reported since the last ERR? query.

The LASer:CALMD command sets the laser's photodiode feedback responsivity
(the CAL PD parameter).

Syntax Diagram

Parameters

An <nrf value>, in mA/mW. The range is 0 to 1000.

Notes

If the parameter is set to 0, the LDX-3232 will operate in a constant I

PD

mode, when

Constant P (MDP) mode is selected.

The parameter should be set to 0 for I

PD

operation modes. Otherwise, the value of this

parameter is used to convert between I

PD

and P

PD

values. The units of this parameter are

mA/mW.

Examples

"LAS:CALMD 0" -action: sets the CAL PD parameter to 0. This enables the constant I

PD

mode of operation.

"Laser:Calmd 1" -action: sets the CAL PD parameter to 1.00 mA/mW. Therefore, a
photodiode feedback current of 1 mA will cause the P

PD

display to read 1 mW.

ERRors?

F

RONT

P

ANEL

R

EMOTE

LASer:CALMD

F

RONT

P

ANEL

R

EMOTE

:

ERR

?

<white

space>

<nrf

value>

:

:

CALMD

CALPD

LAS