Diagrams, Installation & operation manual, Warning – Lochinvar Knight 80 - 285 User Manual

Page 71: Caution high voltage spark lead, 120 vac low voltage high voltage, Figure 13-2 wiring diagram, Continued)

Advertising
background image

Installation & Operation Manual

71

DISPLAY

X1-8

X5-5

X5-13

X5-6

X5-12

INTEGRATED CONTROL

BLOWER

X1-1

X2-2

X2-1

X1-7

GAS
VALVE

FLAME
ROD

SPARK

ROD

W/R

G

R

R

T

W

BK

G

R

1

3

2

W

G

BOX DEPICTS

OPTIONAL ITEMS

WIRING DIAGRAM
LBL7082 REV E

WARNING

DISCONNECT POWER

BEFORE SERVICING

INLET
SENSOR

OUTLET
SENSOR

FLUE
SENSOR

MANUAL RESET
HI-LIMIT

BLOCKED
DRAIN

X5-8

X5-1

X5-2

X5-9

X5-7

X5-14

X5-11

X5-3

X5-4

X5-10

BK

R

W

Y

BL

PR

OR/BK

P

OR

GY

BL

PR

OR

P

OR

GY

1 2

4 5

3

SYSTEM

SENSOR

(AUX) DHW

TANK

SENSOR

OUTDOOR

SENSOR

0-10V

+

-

RS485

A

B

CONNECTION BOARD

CN3

X4

X1-3

X1-5

X1-2

X1-6

X1-4

120V
SUPPLY

BOILER
PUMP

DHW
PUMP

SYSTEM
PUMP

JUNCTION

BOX

TERMINAL STRIP

OR

W

PR

BK

BR

OR

W

PR

BK

BR

W

W

W

L

N

ON/OFF

SWITCH

L

GND

N

SHIELD

SHIELD

BK

Y

FLOW

SWITCH

GAS

PRESSURE

SWITCH

AUX.

DEVICE

PROVING

LOW

WATER

CUT-OFF

CN5-1

CN4-6

CN4-1

CN4-9

CN4-3

CN4-2

X6-9

X6-3

X6-4

X6-5

X6-10

BR

Y

P

BK

OR

CN4-11

CN4-12

CN4-10

CN4-4

ALARM

CONTACTS

RUN-TIME

CONTACTS

X3-1

X3-3

X3-4

X3-2

R

R

PR

PR

AUX.

DEVICE

PILOT

SUPPLY

CN4-8

X6-8

Y

DHW

THERMOSTAT

CN4-5

X6-1

W

ROOM

THERMOSTAT

ZONE

CONTROL

CN4-7

CN4-13

X6-2

X6-6

BL

GY

R

EXTERNAL

CONTROL

AUTO RESET
HI-LIMIT

CAUTION

HIGH VOLTAGE SPARK LEAD

CN5-3

CN5-4

CN5-2

24 VAC

COM

L

N

L

N

L

N

GND

GND

GND

GND

TR1

X8

120 VAC

LOW VOLTAGE

HIGH VOLTAGE

X3

PC

INTERFACE

CN4-14

CN1-12

CN1-11

CN1-10

CN1-9

CN1-8

CN1-7

CN1-6

CN1-5

CN1-4

CN1-3

CN1-2

CN1-1

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

CN2-1

CN2-2

CN2-3

CN2-4

CN2-5

CN2-6

CN2-7

CN2-8

CN2-9

CN2-10

CN2-11

CN2-12

CN2-13

CN2-14

CN2-15

CN2-16

CN1

CN2

CN5

CN4

CN3

BELL JUMPER

ALA

R

M BEL

L

S

ILE

NCING S

W

IT

CH

S6

S4

S5

S2

S1

S3

KB

MODELS

ONLY

AIR PRESSURE
SWITCH

OR

R

ESIST

O

R

Figure 13-2 Wiring Diagram