2 6

Maintenance

Travis Industries

4 0 5 1 2 1 6

9 3 5 0 8 0 5 1

Yearly Maintenance (or every two tons)

WARNING:

Disconnect the power cord prior to conducting service.

The following section details extensive maintenance procedures. We strongly suggest these items
be carried out by a trained service technician, possibly by a service agreement set up with your dealer.

Soot and Flyash: Formation and Need for Removal – The products of combustion will
contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect
operation of the room heater will lead to some soot formation which will collect in the exhaust venting
system The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.

Clean the Vertical Exhaust Duct

(the stove must be cool and unplugged)

Remove both
refractory side clips.

Remove the
refractory.

Clean this area

behind where the
refractory rests

(both sides).

Remove these doors to
remove fallen flyash and

soot (see “Bi-Weekly
Maintenance for details”)

Clean the Exhaust Duct

(make sure the heater is cool and unplugged)

Remove the surround panels (see page 11).
You may wish to disconnect the vent and

pull the insert forward to gain better access.

Remove the cover
plates over the exhaust

duct (both sides)

b

5/16" Nutdriver

Cover
Plate

Use a vacuum

or bottle brush
to remove all

flyash from the
exhaust duct.

a

c

Advertising