Specifications

5

Travis Industries

4 0 5 1 2 1 6

9 3 5 0 8 0 5 1

Heating Specifications:

Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 1,600 Sq. Feet
Burn Rate (Pounds per Hour)**............................................................................1.0 to 3.5
Maximum Burn Time on Low Burn** ......................................................................10 - 30 Hours
Hopper Capacity ..............................................................................................35 Pounds

*

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the fuel size, quality, and moisture level.

* *

Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20%
depending on fuel quality may occur.

Dimensions:

22"

28-7/8”* for

8” x 10” Panels

31-7/8”* for

10” x 13” Panels

40-1/2”* for 8” x 10” Panels

44-1/2”* for 10” x 13” Panels

* Includes trim and the required 3/8” gap between the surround panels and fireplace.

Center of 3” diameter Flue is 9-3/8” above
the baseplate and 5-1/8” left of center

9-1/2"*

11-5/8"*

19-5/8"

18-5/8"

22-1/8”

Measure
clearances to
the hopper lid.

Electrical Specifications:

Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence ...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)

Fuel:

The unit is designed for wood pellets that comply with the standards set by the Association of Pellet Fuel
Industry (density of at least 40 lbs. per cubic foot, 1/4" to 5/16" diameter, length no greater than 1–1/2", 8200
BTU's/lb., moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). If the fuel
does not comply to this standard, the unit may not operate as designed.

EPA Compliance:

This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test
methods by OMNI Test Labs.