Air Flow Balancing

Place pitot tube a minimum of 18" from blower or elbows

Note: Duct connections may vary,
depending on model.

Outdoors

MAGNEHELIC

Pitot

tube

Magnehelic

gauge

MAGNEHELIC

Magnehelic

gauge

Pitot

tube

Additional dampers
may be required

Placement of Pitot Tube HRV

MAGNEHELIC

DUCT

AIR

FLOW

Pitot tube

High Pressure Side

Low Pressure Side

Magnehelic gauge

Pitot Tube and Gauge

Pitot Tube Air Flow Balancing Kit

Part No. 99-167

1 - magnehelic gauge
1 - Pitot Tube and hose
1 - Carry Case

ATTENTION

Apply use of balancing dampers as
required.

Push and turn with slotted
screwdriver. Damper

automatically locks when

pressure is released.

When connecting ductwork to the collar, take
note where screws are located. Screws should
be located no further

than 1/2” from outside edge of collar, so as not
to impede operation of the damper.

1/2”

Hard/Rigid

ducting

Insulated flexible

ducting

Installations where the HRV is ducted
directly to the return of a furnace may
require additional dampening on the fresh air
to building duct.

This is due to the high return static pressures
found in some furnace installations.

Balancing Collar Instructions

Often the “Fresh Air to House” ducting will have the heaviest air flow which must be dampered down. A Balancing Damper is
located in the “Fresh Air to House” collar. The Balancing Collar feature is not available on all models.

NOTE

Graphic is for illustrative purposes only. Duct
connection ports may vary.