Net socket (applies to 3000 mxp net only), Net socket, Interfaces and sockets – codec 3000 mxp – TANDBERG 6000MXP User Manual

Page 26

Advertising
background image

26

D 13887.08
MAY 2008

TANDBERG 3000

MXP

&

6000

MXP

REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Interfaces and Sockets – Codec 3000

MXP

V35 DTE DCE

Pin

Signal name

Direction

Description

1

FGND

Frame GND on equipment

11

SD(A)

Send Data / Transmit

12

SD(B)

Send Data / Transmit

13

RD(A)

Receive Data

14

RD(B)

Receive Data

15

SCR(A)

Signal Clock Receive

16

SCR(B)

Signal Clock Receive

17

SCT(A)

Signal Clock Transmit

18

SCT(B)

Signal Clock Transmit

19

GND

1

Signal GND

22

RLSD(CD)

Received Line Signal Detector /
Carrier Detect

23

RLSD(GND)

1

Signal GND

24

RI

Ring Indicator

25

LOS

Loss of Signal (KG194)

26

DTR

Data Terminal Ready

1) This pin is connected to ground for correct operations

RS449 DTE DCE

Pin

Signal name

Direction

Description

1

FGND

Frame GND

11

SD(A)

Send Data

12

SD(B)

Send Data

13

RD(A)

Receive Data

14

RD(B)

Receive Data

15

RT(A)

Receive Timing

16

RT(B)

Send Timing

17

ST(A)

Send Timing

18

ST(B)

Send Timing

19

GND

1

GND

20

TR(A)

Terminal Ready

21

TR(B)

Terminal Ready

22

RR(A)

Carrier Detect / Receiver Ready

23

RR(B)

Carrier Detect / Receiver Ready

24

IC

Incoming Call

25

LOS

Loss of Signal (KG194)

Frame GND is connected to pin 1 on DTE
1) This pin is connected to ground for correct operations

X.21 DTEDCE

Pin

Signal name

Direction

Description

1

FGND

Frame GND

11

T(A)

Send Data / Transmit

12

T(B)

Send Data / Transmit

13

R(A)

Received Data / Receive

14

R(B)

Received Data / Receive

15

S(A)

Signal Element Timing

16

S(B)

Signal Element Timing

20

C(A)

Terminal Ready / Control

21

C(B)

Terminal Ready / Control

22

I(A)

Carrier Detect

23

I(B)

Carrier Detect

Net interface socket.

1 × X.21 / V.35 / RS449

with 1 × RS366 Call Control up to 2 Mbps

Note the following:

V.10 (RS423).

For balanced signals a

0 = low voltage

, is defined as terminal

A positive with respect to terminal B.
For unbalanced signals a

0 = low volt-

age

, is defined as terminal positive

with respect to GND. Cable length
for

Leased Line Control

should not

exceed 20 m.

RS 366.

All balanced inputs and

outputs (A and B) use balanced line
signals according to V.11 (RS 422),
while single ended signals are in
accordance with V.10 (RS423). The

0 = low voltage

definitions are the

same as for V.10 above. Max cable
length, as for V.10 above.

X.21.

Signals are as for RS 366 above.

Cable length should not exceed 50 m.

RS366 DTE DCE

Pin

Signal name

Direction

Description

1

FGND

Frame GND

2

DPR

Digit Present

3

ACR

Abandon Call & Retry

4

CRQ

Call Request

5

PND

Present Next Digit

6

DLO

Data Line Occupied

7

NB1

Digit Bit 1

8

NB2

Digit Bit 2

9

NB4

Digit Bit 4

10

NB8

Digit Bit 8

HD D-SuB 26 pin-out

External view of socket

9

1

10
19

18
26

Net socket (applies to 3000 MXP Net only)

Advertising