Programming Pg. 14


0 = NO OUTPUTS
1 = SCALED PULSE OUTPUT & LOW ALARM
2 = UNSCALED PULSE OUTPUT & LOW ALARM

0 = SECOND, 1 = MINUTE, 2 = HOUR, 3 = DAY

RATE TIM EBASE

0

CAL 05

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

0
1
2
3

TOTAL DISPLAY

PLACES AFTER DECIM AL

0

CAL 07

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

0
1
2
3

K-FACTOR

DIGITS AFTER DECIM AL

PROGRAMMING

INITIATE – REMOVE & REVERSE BOTTOM STRIP

EXIT – REPEAT ABOVE STEP

TOTAL

1468523

RATE

79.4

0
1
2

PULSE OUTPUT

K-FACTOR

WHOLE NUM BERS

0

CAL 00

PROGRAM

000000

CAL 01

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

0-999999

SOFT

000000

CAL 02

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

.000001 - .999999

COMBINATION
CAN’T EXCEED
6 DIGITS

CUTOFF

FREQUENCY

000

CAL 03

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

.0.01 - .99 HZ DEFAULT @2.5 HZ

RATE DISPLAY

PLACES AFTER DECIM AL

0

CAL 04

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM


0
1
2
3

FILTER

01

CAL 06

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

1

99

TOTAL CONVERSION

FACTOR WHOLE NUM BERS

TOTAL CONVERSION

DIGITS AFTER DECIM AL

COMBINATION
CAN’T EXCEED
6 DIGITS

000000

CAL 08

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

0 - 999999

000000

CAL 09

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

.000001 - .999999

COMBINATION
CAN’T EXCEED
6 DIGITS

000000

CAL 10

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

0 - 999999

000000

CAL 11

PROGRAM

PRESS

 KEY TO INCREMENT FLASHING DIGIT

PRESS

 KEY TO ADVANCE TO NEXT DIGIT

PRESS PROGRAM TO ADVANCE TO NEXT MENU ITEM

.000001 - .999999

LOW ALARM

WHOLE NUM BERS

LOW ALARM

DIGITS AFTER DECIM AL

CONTINUED ON NEXT PAGE

0 = FLASHING DIGIT

1 - 999999

.000001 - .999999

Advertising