Specifications, Typical connection, Connection to a sensor requiring external power – Liquid Controls IT375 User Manual

Page 19

Advertising
background image

Sponsler, Inc.

Model IT375

Versions Pg. 19


6.3 RELAY AND 4-20mA OUTPUT VERSION


This version combines features of the DC powered with a 4-20mA output.

The 4-20mA output provides a two-wire retransmission of the flow rate. Both the 4mA and 20mA setpoints are fully
programmable so that the output can span either the entire operating range or only a portion.

The instrument draws its operating power from the 4-20mA loop and uses the internal lithium batteries for backup if the
4-20mA loop is interrupted. The alarm/pulse outputs are disabled if the 4-20mA loop is interrupted.


Specifications:


Resolution and Linearity: 0.05% of span.
Accuracy:

0.05% of span at 25°C.

0.1% (typ) of span, full temperature range.

Response (4-20mA):

0.5 second.

Loop Power Supply:

9-28 Volts.



Since the 4-20mA output is designed to provide power to the Model IT375, it is not isolated from the input. Hence, all
sensors must be self-powering (such as reed switches and coils). If external power is required to power the sensor (eg.
Namur switches, Hall effect sensors or opto-sensors), the power supply delivering the external power must be isolated
from the 4-20mA loop supply.



Typical Connection










Connection to a Sensor requiring External Power












Advertising