8.4 ALARM OUTPUTS


The low alarm and high alarm/pulse output can be connected to suitably certified devices provided the circuit is protected
with a barrier with the maximum safety parameters:

Uo = 28V

Io = 93mA

Pmax = 0.653W


The input capacitance on these terminals is 0.1uF max and the inductance is negligible.

Note: The two alarm outputs must be kept as independent IS circuits and each protected with their own barrier. It is not
permissible to connect these circuits via a common barrier.

IS CERTIFIED BARRIER

Uo = 28 V maximum
Io = 93 mA maximum
Po = 653 mW maximum


SAFE AREA

HAZARDOUS AREA

4 or 6

3 or 5

MODEL IT375

IS Certified Device
Such as an Alarm Lamp