Specifies the HBA port ID of the HBA port for which I/O information is to

be displayed. The subsequent parameters specify the display interval and

count. The format for the subsequent parameters are as follows:

-intvl interval

Specifies the interval at which I/O information is to be displayed, in

the range from 1 to 60 (seconds). When this parameter is omitted,

the default (3 seconds) is applied.

-count count

Specifies the number of times I/O information is to be displayed, in

the range from 1 to 999. When this parameter is omitted, the default

(10) is applied.

-t

Omits the title for each information item.

Table 6-22 Items displayed as I/O information for each HBA port

Item

Description

HbaID

HBA port ID

Port.Bus

Port (host port number in hexadecimal) and Bus (bus number

in hexadecimal) separated by a period

Physical
Device

HBA port configuration information. The names of the physical

device files under the /devices directory are displayed.

StartTime

Date and time in which the command began executing, in the

format yyyy/mm/dd hh:mm:ss

ElapsedTime

Time elapsed since command execution began, in the format

hh:mm:ss

IO-Count

Total I/O count for the displayed paths during a specified

interval indicated by a whole number (indicated by a decimal
number). The maximum value that can be displayed is 2

32

- 1

(4294967295). If the total I/O count reaches the maximum

value, it is reset, and the count is re-started from 0.

IO-Errors

Total I/O error count for the displayed paths during a specified

interval, indicated by a whole number (indicated by a decimal
number). The maximum value that can be displayed is 2

32

- 1

(4294967295). If the total I/O error count reaches the

maximum value, it is reset, and the count is re-started from 0.

Example

# /opt/DynamicLinkManager/bin/dlnkmgr monitor -hbaid 0 -intvl

30 -count 3

HbaID : 00000

Port.Bus : 0001.0000

Physical Device : /devices/pci@8,70000/JNI,FCE@2

StartTime : yyyy/mm/dd hh:mm:ss

ElapsedTime IO-Count IO-Errors

00:00:30 223 10

00:01:00 1140 1

6-70

Command Reference

Hitachi Dynamic Link Manager User Guide for Solaris

®