Australian Monitor Zone Mix 3 User Manual

Page 8

Advertising
background image

8

INSTALLATION SERIES

Australian Monitor

NOTE: This stud provides a connection to chassis ground. Audio ground is internally

tied to chassis ground.

6. REMOTE PORT

7. REMOTE ENABLE

8. LINK

9. EARTH

10. AC POWER

This CAT5 socket is used to connect the optional ZM3R remote control panel for each
zone. See Installation Section on page 13 and Remote Control Panel Section on page 18.

This button puts the zone into remote mode and must be pressed in when using the
remote control panel ZM3R. When pressed, the front panel program controls (SELECT and
LEVEL) will be disable. Control is handed over to the remote control panel. If no remote
control panel is connected, the program inputs will be off.

This 15 pin high density connector is used to connect two ZoneMix3 units together. When
connected together the program sources and the mic/line inputs are linked to the slave
unit. The unit needs to be internally configured as master or slave. This is done by moving
the link cable. See Internal Adjustments on page 10.

In some circumstances it may be necessary to ground the unit to eliminate noise in the
system. This can be done by using this earth stud.

This 2.1mm connector accepts power from the provided 20VAC power supply.

Advertising