Hanging the tubes, Fig. 7, Round tube hangers – L.B. White Oval 80™ Radiant User Manual

Page 11: Oval tube hangers

Advertising
background image

HANGING THE TUBES

Refer to Fig. 7 and the following instructions:

1. Slide a 3 in. round tube clamp over the non-swaged

end of 10 ft. bright aluminized tube. (One aluminized

tube per heater.)

2. Install the round tube over the swaged discharge tube

on the burner box.

3. See the illustration below for remaining tube, clamp,

and hangers.

a. Weld seam of round tube must be down.
b. Clamps must be centered over tube connections.
c. Clamp bolts must be up.
d. Clamp bolts must be tight.

-- Tighten both bolts firmly.

-- Tighten both bolts to 35 ft.-lbs.

-- Finish tightening bolts to 44-59 ft.-lbs.

4. Slide on hangers and connect to chains.

5. The tube assembly should be either hung level, or

with a downward slope away from the burner box not

exceeding 1 in. for every 10 ft. of tube.

FIG. 7

11

ROUND TUBE

WELD SEAM DOWN

CLAMP CENTERED OVER
SWAGED DISCHARGE TUBE
AND 3 IN. ROUND TUBE.

CLAMP UP

ROUND TUBE HANGERS

THIS

NOT THIS

THIS

NOT THIS

OVAL TUBE HANGERS

3 IN. ROUND TUBE

OVAL TUBE

3 IN. ROUND CLAMP