Manual shut-off valve, hose & regulator assembly, Fig. 12, Fig. 9 fig. 10 – L.B. White Oval 80™ Radiant User Manual

Page 13: Fig. 11

Advertising
background image

GAS HOSE

ADAPTER

SEDIMENT TRAP

TO CONTROL

VALVE INLET

GA

1. Assemble the components together. See Fig. 12.

The regulator must always be mounted so its vent,

regardless of location on the regulator, is always

pointed downward. If the regulator is vented outside,

venting must be directed down. Ensure hose is

positioned away from the heater.

2. Tighten all connections securely and check for gas

leaks.

FIG. 12

Assemble the strips and insert into last tube. Edge of strip

is flush with end of tube. See Fig.9. Refer to Fig.10 for

installation of flapper.

FIG. 9

FIG. 10

MANUAL SHUT-OFF VALVE, HOSE

& REGULATOR ASSEMBLY

13

Assemble the tee, nipple, and cap to the nipple at the gas

inlet of heater. See Fig. 11. Tighten securely. The sediment

trap assembly must always be mounted in a vertical

position. Check all connections for gas leaks using

approved gas leak detectors.

FIG. 11

AIR TURBULATION STRIPS & VENT CAP

SEDIMENT TRAP ASSEMBLY

NIPPLE

HOSE ADAPTER

TEE

NIPPLE

CAP

TO GAS CONTROL

VALVE INLET

NIPPLE

VALVE, MANUAL
SHUT-OFF

REGULATOR

OVAL TUBE

NIPPLE

VENT

PUSH THE CAP FIRMLY ONTO END OF
OVAL TUBE, UNTIL TUBE HITS THE
STOPS OF THE CLAMP. TIGHTEN
CLAMP SCREWS SECURELY.