Heater specifications, Model – L.B. White Oval 80™ Radiant User Manual
Page 4
Heater Specifications
4
AR080
20
80,000
3.70
80
13.5 in. W.C., L.P. and Natural Gas
11.0 in. W.C., L.P. Gas
7.0 in. W.C., Natural Gas
10.0 in. W.C., L.P. Gas
4.0 in. W.C., Natural Gas
140 CFM
Ball Bearing
1/30 H.P., 3020 RPM, CW Rotation
115/60/1
STARTING
1.16
CONTINUOUS
OPERATION
TOP
1 ft.
SIDES
2.5 ft.
DISCHARGE END
6 ft.
BELOW RADIANT
6 ft.
12-18 in. Above Litter and Approx. 10 Ft. Down from Burner Box
Ventilation Air Required
to Support Combustion
Minimum Safe
Distances of Heater
From Nearest
Combustible Materials
(See Fig. 1 on page 5)
Amp Draw
(Starting Amps
Include Igniter)
Motor Characteristics
1.02
Temperature Sensor Location
(See Fig. 2 on page 5)
SPECIFICATIONS
Model
Inlet Gas Supply
Pressure Acceptable
at the Inlet of the
Heater for Purpose of
Input Adjustment
Input per Hour (BTUH)
Tube Length (ft.)
MAX.
MIN.
BurnerManifold
Pressure
Fuel Consumption
per Hour (Max.)
Electrical Supply (Volts/Hz/Phase)
L.P. GAS (lbs.)
NAT. GAS (cu. ft.)